Preguntas Frecuentes
- ¿Ofrecen envío internacional para sus productos? ❯
- ¿Cómo puedo pagar mi pedido en Balticdiag.com? ❯
ENTREGA GRATUITA A TODO EL MUNDO PARA TODOS LOS PRODUCTOS!
El Carro de Compras está vacío.
Is an acquisition instrument for analogue and digital measures. It is a powerful, functional and economic acquisition system in the world of cars, bikes and industrial vehicles diagnosis.
TwinProbe communicates with all TEXA viewing units or with a Windows PC with USB connection or through Bluetooth Technology, allowing the mechanic absolute freedom of movement around the vehicle and in the workshop.
The tool can be managed by the IDC5 operating software, or MSS (Measurement System Software) when used on a PC.
1. Green LED: indicates that the tool is on.
2. Red LED: indicates the battery status.
3. Blue LED: indicates the Bluetooth communication status.
4. USB plug: USB 2.0 connector (compatibile USB 1.0) for communication with the display unit and for firmware update of the tool.
5. Power: ON/OFF button.
6. Battery Power: connection connector for mains adapter or battery clamps.
7. Gen. Function: connector for signal generator.
8. CH02: input of channel 2 of the oscilloscope.
9. CH01: input of channel 1 of the oscilloscope
TwinProbe is an oscilloscope with two independent analogue channels for inputs up to ± 200V, complete with SIV (Signal information Viewing ) function for interpreting the measured signal.
The SIV function guides you through the entire test procedure. TwinProbe not only displays the signal but, while taking measurements and acquiring data, simultaneously processes and analyses information in order to provide real time evaluations.
TwinProbe can process signals from various sensors and actuators and compare the data acquired against values stored in the internal database, immediately highlighting any signal anomalies.
Sí, ofrecemos envío internacional exprés rápido y gratuito para todos los productos disponibles en Balticdiag.com. Realizamos entregas a todo el mundo — incluyendo USA, Europa, América del Norte, América del Sur, Asia, África y Australia — utilizando servicios de mensajería confiables como DHL, UPS y FedEx. Cada pedido se envía con entrega exprés directamente a tu puerta, garantizando una llegada rápida y segura. Los costos de envío están incluidos en el precio del producto, y proporcionamos información de seguimiento completa para que puedas monitorear tu paquete desde el despacho hasta la entrega.
Aceptamos una amplia variedad de métodos de pago seguros internacionales y locales, incluyendo:
POWER SUPPLY
8 V – 35 V DC max
STAND-BY CONSUMPTION
150 mA at 12 V
CONSUMPTION DURING BATTERY CHARGE IN OSCILLOSCOPE MODE AND 2 ACTIVE CHANNELS
480 mA at 12 V
INTERNAL BATTERY DURATION IN OSCILLOSCOPE MODE AND 2 ACTIVE CHANNELS
1h and 45 mins approximately
ENVIRONMENTAL
Operational temperature: 0 ÷ +45°C
Storage temperature: – 20 °C ÷ 60 °C
Operating relative humidity: 10% – 80%
DIMENSIONS WITHOUT CABLES (WITH CABLES)
125 x 130 x 27 mm (135 x 130 x 27 mm)
WEIGHT
460 g
OSCILLOSCOPE:
CHANNEL NUMBERS
2 analogue (CH01, CH02)
HOST CONNECTION
Via USB2, USB1 or Wireless Bluetooth
TRIGGER
CH01 o CH02
A/D CONVERSION
2 10-bit converters.
40 MS/s with one active channel.
20 MS/s for channel with 2 active channels
VIEWING MODE
Normal, Auto, Single shot
COMMON MODE
AC, DC
MAX INPUT VOLTAGE
± 200 V
ADDITIONAL FUNCTIONS
Trigger delay, frequency calculation, Vmedia, Vmax, Vmin, Period, Setting scale for amperometric clamps
SIGNAL GENERATOR:
PWM CURRENT DRIVE
Maximum continuous current: 5 A at 12 V
Maximum PWM frequency: 50 kHz
Operating voltage: 5÷30 V
Duty Cycle Resolution: 1%
Frequency resolution: 0,1 Hz
PWM 5 V
Maximum continuous OUTPUT
current: 20 mA
Maximum PWM frequency: 50 kHz
OUTPUT voltage: 0-5 V ± 5%
Duty Cycle Resolution: 1%
Frequency resolution: 0,1 Hz
Two independent analogue channels, with an input range of up to ± 200V, equipped with SIV function for the correct interpretation of the signal plots.
To simulate the pulses generated by sensors and reproduce the commands generated by control units.
This function can be accomplished through oscilloscope function in combination with BICOR clamp.
TwinProbe, like all TEXA instruments, use the operative environment IDC4, the diagnosis and self-diagnosis software with built-in databank and exceptional coverage of makes and models.
IDC4 is available both in a standard version for PC, MULTI PEGASO and AXONE 4, as well as in a POCKET version for portable viewing units of the AXONE line, but the software potential is the same in all. The wireless Bluetooth connection or connection via USB cable, allows for the transfer of data from the instrument to the viewing unit.
For those not having and not wishing to acquire the complete operative platform IDC4, MSS (Measurement System Software) is available, specific for TwinProbe, which enables only the functions of oscilloscope, battery probe, TNET, multimeter, pressure test and signal generator in manual mode.
The oscilloscope test carried out with TwinProbe guarantees excellent detection of values and a precise identification of the measurement; but what the mechanic most needs is an efficient system to help him correctly identify the graphs processed by the instrument. In order to declare if the signal analysed is correct or not, it is, however, necessary to have reference data, values that clearly show which are the critical points to be analysed.
This is why TEXA has developed a support that guides the mechanic throughout the test. The function developed is a software algorithm named S.I.V. (Signal Information Viewing). Thanks to this system, TwinProbe do not simply view the signal; as they take the measurements and acquire the data, they process all information, analyse it and supply an assessment in real time.
They are, in fact, able to process the signals of the various sensors or actuators concerned by the measurement and compare the data acquired with that present in the internal database, thereby immediately showing any signal anomalies. This mode can be used simply and quickly, starting from the wiring diagram of the system to be analysed or the list of components.
By selecting the device to be verified, we automatically activate the oscilloscope, which is already configured to correctly test the component.
TwinProbe are two instruments offering exceptional performance and extremely high reliability levels. Whilst TwinProbe incorporates a digital oscilloscope with a channel for 40 Msamples/sec or two channels for 20 Msamples/sec with inputs extended up to ± 200 Volts. This performance is distinctly higher than that offered by other solutions available on the market.
TwinProbe are able to operate as a PWM signal generator for device testing. Tests can be carried out on mechanical components such as actuators, pressure switches of diesel engines, turbine blades or the EGR valve. Thanks to UNIProbe and TwinProbe, it can be assessed whether the anomaly depends on an electronic malfunction or a mechanical breakage. By using UNIProbe and TwinProbe in combination with the software IDC4, adjustments can be made and the effects observed by comparing them with the parameters proposed by the self-diagnosis
Oscilloscope and signal generator, USB or Bluetooth connection, complete with standard low tension cable, USB cable, vehicle battery power cable, manual and software.
The following image displays the tips supplied with the tool:
POWER SUPPLY
8 V – 35 V DC max
STAND-BY CONSUMPTION
150 mA at 12 V
CONSUMPTION DURING BATTERY CHARGE IN OSCILLOSCOPE MODE AND 2 ACTIVE CHANNELS
480 mA at 12 V
INTERNAL BATTERY DURATION IN OSCILLOSCOPE MODE AND 2 ACTIVE CHANNELS
1h and 45 mins approximately
ENVIRONMENTAL
Operational temperature: 0 ÷ +45°C
Storage temperature: – 20 °C ÷ 60 °C
Operating relative humidity: 10% – 80%
DIMENSIONS WITHOUT CABLES (WITH CABLES)
125 x 130 x 27 mm (135 x 130 x 27 mm)
WEIGHT
460 g
OSCILLOSCOPE:
CHANNEL NUMBERS
2 analogue (CH01, CH02)
HOST CONNECTION
Via USB2, USB1 or Wireless Bluetooth
TRIGGER
CH01 o CH02
A/D CONVERSION
2 10-bit converters.
40 MS/s with one active channel.
20 MS/s for channel with 2 active channels
VIEWING MODE
Normal, Auto, Single shot
COMMON MODE
AC, DC
MAX INPUT VOLTAGE
± 200 V
ADDITIONAL FUNCTIONS
Trigger delay, frequency calculation, Vmedia, Vmax, Vmin, Period, Setting scale for amperometric clamps
SIGNAL GENERATOR:
PWM CURRENT DRIVE
Maximum continuous current: 5 A at 12 V
Maximum PWM frequency: 50 kHz
Operating voltage: 5÷30 V
Duty Cycle Resolution: 1%
Frequency resolution: 0,1 Hz
PWM 5 V
Maximum continuous OUTPUT
current: 20 mA
Maximum PWM frequency: 50 kHz
OUTPUT voltage: 0-5 V ± 5%
Duty Cycle Resolution: 1%
Frequency resolution: 0,1 Hz
Two independent analogue channels, with an input range of up to ± 200V, equipped with SIV function for the correct interpretation of the signal plots.
To simulate the pulses generated by sensors and reproduce the commands generated by control units.
This function can be accomplished through oscilloscope function in combination with BICOR clamp.
TwinProbe, like all TEXA instruments, use the operative environment IDC4, the diagnosis and self-diagnosis software with built-in databank and exceptional coverage of makes and models.
IDC4 is available both in a standard version for PC, MULTI PEGASO and AXONE 4, as well as in a POCKET version for portable viewing units of the AXONE line, but the software potential is the same in all. The wireless Bluetooth connection or connection via USB cable, allows for the transfer of data from the instrument to the viewing unit.
For those not having and not wishing to acquire the complete operative platform IDC4, MSS (Measurement System Software) is available, specific for TwinProbe, which enables only the functions of oscilloscope, battery probe, TNET, multimeter, pressure test and signal generator in manual mode.
The oscilloscope test carried out with TwinProbe guarantees excellent detection of values and a precise identification of the measurement; but what the mechanic most needs is an efficient system to help him correctly identify the graphs processed by the instrument. In order to declare if the signal analysed is correct or not, it is, however, necessary to have reference data, values that clearly show which are the critical points to be analysed.
This is why TEXA has developed a support that guides the mechanic throughout the test. The function developed is a software algorithm named S.I.V. (Signal Information Viewing). Thanks to this system, TwinProbe do not simply view the signal; as they take the measurements and acquire the data, they process all information, analyse it and supply an assessment in real time.
They are, in fact, able to process the signals of the various sensors or actuators concerned by the measurement and compare the data acquired with that present in the internal database, thereby immediately showing any signal anomalies. This mode can be used simply and quickly, starting from the wiring diagram of the system to be analysed or the list of components.
By selecting the device to be verified, we automatically activate the oscilloscope, which is already configured to correctly test the component.
TwinProbe are two instruments offering exceptional performance and extremely high reliability levels. Whilst TwinProbe incorporates a digital oscilloscope with a channel for 40 Msamples/sec or two channels for 20 Msamples/sec with inputs extended up to ± 200 Volts. This performance is distinctly higher than that offered by other solutions available on the market.
TwinProbe are able to operate as a PWM signal generator for device testing. Tests can be carried out on mechanical components such as actuators, pressure switches of diesel engines, turbine blades or the EGR valve. Thanks to UNIProbe and TwinProbe, it can be assessed whether the anomaly depends on an electronic malfunction or a mechanical breakage. By using UNIProbe and TwinProbe in combination with the software IDC4, adjustments can be made and the effects observed by comparing them with the parameters proposed by the self-diagnosis
Oscilloscope and signal generator, USB or Bluetooth connection, complete with standard low tension cable, USB cable, vehicle battery power cable, manual and software.
The following image displays the tips supplied with the tool: